Chamberlain Swing GATE Safety Gate User Manual


 
30 of 53 Doc 6001242 (01-20273) Rev C
There are 2 different ways to close the gate (entering or exiting):
1. Reclose Timer: When the Reclose Timer expires, gate closes automatically (Master or Slave).
2. Interrupt Loop; clearing the Inside Interrupt Loops cause the gates to close (Master or Slave).
NOTE: To ensure gate closure, set Reclose Timer =ON in both Master and Slave
INPUT CONNECTIONS: (for more details, refer to Part 2, Paragraph L, Connecting Input Wiring)
Master and Slave units require their own separate inputs.
If Radio inputs are used in both units, each requires its own transmitter and entry code.
MASTER UNIT SWITCH S1 SETTINGS AND INPUTS
Gate
Type
SLIDE
ACTION
(Reclose)
TIMER
RETRY ATG MASTER TRAP
Operator
Inputs
Trap
Unit
Optionn
Unit
Optionn
Unit
Optionn
ON ON ON Unito
SLAVE UNIT SWITCH S1 SETTINGS AND INPUTS
Trap
Unit
Optionn
Unit
Optionn
Unit
Optionn
No Effect OFF OFF Unito
n:
Master and Slave units can have different Reclose Timer settings.
o:
Inputs affect one gate operator only, so connect inputs separately to each gate operator.