Chamberlain Swing GATE Safety Gate User Manual


 
Rev C Doc 6001242 (01-20273) 17 of 53
2. RECLOSE TIMER ENABLE (S1) AND SET (R94)
Figure 11. Reclose Timer Enable and Adjustmment Location.
The Reclose Timer pot (R94) is adjustable from 0 to 250 seconds. Turning the pot clockwise
increases the reclose time. NOTE: Pot in figure is set to 0 seconds.
1. To enable the Timer, set switch S1-2 (TIMER) to the ON (right) position.
2. Turn the pot fully counterclockwise.
3. Open the gate. Gate should close almost immediately when it reaches the open limit.
4. Adjust the pot slightly clockwise.
5. Open the gate. Note the delay between the gate reaching the open limit and starting to
close.
6. Repeat steps 4 and 5 until the desired relcose time is set.