BenQ MP612c Crib Toy User Manual


 
Maintenance 53
Replacing the lamp
To reduce the risk of electrical shock, always turn the projector off and disconnect the
power cord before changing the lamp.
To reduce the risk of severe burns, allow the projector to cool for at least 45 minutes
before replacing the lamp.
To reduce the risk of injuries to fingers and damage to internal components, use caution
when removing lamp glass that has shattered into sharp pieces.
To reduce the risk of injuries to fingers and/or compromising image quality by touching
the lens, do not touch the empty lamp compartment when the lamp is removed.
This lamp contains mercury. Consult your local hazardous waste regulations to dispose of
this lamp in a proper manner.
To assure optimal performance from the projector, it is recommended that you purchase a
BenQ projector lamp for lamp replacement.
If lamp replacement is performed while the projector is suspended upside-down from the
ceiling, make sure that no one is underneath the lamp socket to avoid any possible injury
or damage to the human eyes caused by fractured lamp.
1. Turn the power off and disconnect the projector from the wall socket. If the lamp is
hot, avoid burns by waiting for approximately 45 minutes until the lamp has cooled.
The lamp has been in operation for 4000 hours.
It is strongly recommended that you replace the
lamp at this age. The lamp is a consumable item.
The lamp brightness diminishes with use. This is
normal lamp behavior. You can replace the lamp
whenever you notice that the brightness level has
significantly diminished. If the lamp is not
replaced beforehand, it must be replaced after 3000
hours usage.
The lamp MUST be replaced before the projector
will operate normally.
OK
Replace Lamp Now
Lamp > 4000 Hours
Lamp usage time exceeded
Notice
OK
Lamp-usage time exceeded
Replace lamp (refer to User's manual)
Then reset lamp timer
Notice
2. Turn the projector over. Then use a coin to
turn the screw counterclockwise until the lamp
cover loosens.