Thecurrentconguration(conguration0)canbesavedasapresetinanyoneof
32presetmemoryaddresses.Presetlocationsareassignedtotheinputbuttonsand
(wherenecessary)outputbuttons.Upto20or32(dependingonthenumberof
input and output buttons) presets can be selected from the front panel to be either
saved or retrieved. When a preset is retrieved from memory, it becomes the current
configuration.
N • Onlytheaudioandvideotiesarestoredandrecalled;RGBdelayandaudio
gain and volume settings are not saved, and they do not change when a preset
is recalled.
• Presetscannot be viewed from the front panel unless recalled as the current
configuration. Presets can be viewed using Extron’s Windows-based control
program. See chapter 5, “Matrix Software”, for more details.
• Thecurrentcongurationandallpresetsarestoredinnon-volatilememory.
When power is removed and restored, the current configuration is still active
and all presets are retained.
• Whenapresetisrecalled,itreplacesthecurrentconguration,whichislost
unless it is also stored as a preset. The recalled preset overwrites all of the
current configuration ties in favor of the preset configuration ties.
• Allmodelshave32presets;onmodelswithfewerthan32inputandoutput
buttons, preset numbers that are too high to be available from the front panel
are still accessible under serial port or Ethernet control.
• Figure3-42showsthepresetsassociatedwiththetwoinputandoutput
button configurations for the CrossPoint and MAV matrix switchers.
I
N
P
U
T
S
1
24 x 12, 24 x 24, 32 x 16, and 32 x 32 matrix sizes
Input
buttons
Input
buttons
Output
buttons
Input
buttons
Output
buttons
Preset
1
8 x 16, 16 x 4, 16 x 8, 12 x 12, and 16 x 16 matrix sizes
Preset
1
Preset
6
Preset
7
Preset
10
Preset
15
Preset
16
Preset
11
Preset
3
Preset
8
Preset
9
Preset
4
Preset
5
Preset
13
Preset
14
Preset
12
Preset
2
Preset
17
Preset
22
Preset
23
Preset
26
Preset
31
Preset
32
Preset
27
Preset
19
Preset
24
Preset
25
Preset
20
Preset
21
Preset
29
Preset
30
Preset
28
Preset
18
Preset
5
Preset
6
Preset
10
Preset
7
Preset
13
Preset
14
Preset
15
Preset
2
Preset
8
Preset
9
Preset
3
Preset
4
Preset
11
Preset
12
Preset
16
Preset
17
Preset
21
Preset
22
Preset
26
Preset
23
Preset
29
Preset
30
Preset
31
Preset
18
Preset
24
Preset
25
Preset
19
Preset
20
Preset
27
Preset
28
Preset
32
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
INPUTS
1
2
3 4
5
6
7
8
9
10
11
12
14
15
16
13
1
2
3
4
5
6
7
8
9
10
11
12
14
15
16
13
OUTPUTS
8 x 4, 8 x 8, 12 x 4, and 12 x 8 matrix sizes
Preset
1
Preset
5
Preset
10
Preset
2
Preset
11
Preset
3
Preset
8
Preset
12
Preset
6
Preset
7
Preset
4
Preset
13
Preset
17
Preset
14
Preset
15
Preset
20
NOTE Presets 21 through 32 are available via RS-232/
RS-422 and Ethernet control only
Preset
18
Preset
19
Preset
16
Preset
9
INPUTS
1
2
3
4
5
6 7
8
9
10
11 12
1
2
3
4
5
6
7
8
OUTPUTS
Figure 3-42 — Preset locations by matrix size