4-5
CrossPoint / MAV Matrix Switchers • Programmer’s Guide
Default IP addresses
ToaccesstheCrossPointorMAVPlusswitcherviatheLANport,youneedthe
ExtronIPaddress,andmayneedthesubnetmaskandthegatewayaddress.Ifthe
IPaddresshasbeenchangedtoanaddresscomprisedofwordsandcharacters,
youcandeterminetheactualnumericIPaddressusingtheping(ICMP)utility(see
appendixA,“EthernetConnection”,formoredetails).Iftheaddresseshavenot
been changed, the factory-specified defaults are:
• IPaddress 192.168.254.254
• Gatewayaddress 0.0.0.0
• Subnetmask 255.255.0.0
Establishing a connection
EstablishanetworkconnectiontoaCrossPointorMAVPlusswitcherasfollows:
1. OpenaTCPsockettoport23usingtheswitcher’sIPaddress.
N
If the local system administrators have not changed the value, the factory-
specified default, 192.168.254.254, is the correct value for this field.
The switcher responds with a copyright message including the date, the name
oftheproduct,rmwareversion,partnumber,andthecurrentdate/time.
N
If the switcher is not password-protected, the device is ready to accept SIS
commands immediately after it sends the copyright message.
N
If the switcher is password-protected, a password prompt appears below the
copyright message.
2. Iftheswitcherispasswordprotected,entertheappropriateadministratoror
user password.
Ifthepasswordisaccepted,theswitcherrespondswithLogin User or
Login Administrator.
Ifthepasswordisnotaccepted,thePassword prompt reappears.
Connection Timeouts
The Ethernet link times out after a designated period of time of no communications.
Bydefault,thistimeoutvalueissetto5minutesbutthevaluecanbechanged.See
theCongureporttimeoutcommandsonpage4-25.
N
Extron recommends leaving the default timeout at 5 minutes and periodically
issuing the Query (Q) command to keep the connection active. If there are long
idle periods, Extron recommends disconnecting the socket and reopening the
connection when another command must be sent.
Number of connections
ACrossPointorMAVPlusswitchercanhaveupto200simultaneousTCP
connections, including all http sockets and Telnet connections. When the
connection limit is reached, the switcher accepts no new connections until some
have been closed. No error message or indication is given that the connection limit
hasbeenreached.TomaximizeperformanceofanIPLinkdevice,thenumberof
connections should stay low and unnecessary open sockets should be closed.