CrossPoint / MAV Matrix Switchers • Programmer’s Guide
Default IP addresses
ToaccesstheCrossPointorMAVPlusswitcherviatheLANport,youneedthe
ExtronIPaddress,andmayneedthesubnetmaskandthegatewayaddress.Ifthe
IPaddresshasbeenchangedtoanaddresscomprisedofwordsandcharacters,
youcandeterminetheactualnumericIPaddressusingtheping(ICMP)utility(see
appendixA,“EthernetConnection”,formoredetails).Iftheaddresseshavenot
been changed, the factory-specified defaults are:
• IPaddress 192.168.254.254
• Gatewayaddress 0.0.0.0
• Subnetmask 255.255.0.0
Establishing a connection
EstablishanetworkconnectiontoaCrossPointorMAVPlusswitcherasfollows:
1. OpenaTCPsockettoport23usingtheswitcher’sIPaddress.
N
If the local system administrators have not changed the value, the factory-
specified default, 192.168.254.254, is the correct value for this field.
The switcher responds with a copyright message including the date, the name
oftheproduct,rmwareversion,partnumber,andthecurrentdate/time.
N
If the switcher is not password-protected, the device is ready to accept SIS
commands immediately after it sends the copyright message.
N
If the switcher is password-protected, a password prompt appears below the
copyright message.
2. Iftheswitcherispasswordprotected,entertheappropriateadministratoror
user password.
Ifthepasswordisaccepted,theswitcherrespondswithLogin User or
Login Administrator.
Ifthepasswordisnotaccepted,thePassword prompt reappears.
Connection Timeouts
The Ethernet link times out after a designated period of time of no communications.
Bydefault,thistimeoutvalueissetto5minutesbutthevaluecanbechanged.See
theCongureporttimeoutcommandsonpage4-25.
N
Extron recommends leaving the default timeout at 5 minutes and periodically
issuing the Query (Q) command to keep the connection active. If there are long
idle periods, Extron recommends disconnecting the socket and reopening the
connection when another command must be sent.
Number of connections
ACrossPointorMAVPlusswitchercanhaveupto200simultaneousTCP
connections, including all http sockets and Telnet connections. When the
connection limit is reached, the switcher accepts no new connections until some
have been closed. No error message or indication is given that the connection limit
hasbeenreached.TomaximizeperformanceofanIPLinkdevice,thenumberof
connections should stay low and unnecessary open sockets should be closed.