Operation, cont’d
CrossPoint / MAV Matrix Switchers • Operation
3-12
Front panel security lockouts
Intheproceduraldescriptionsthatfollow,itisassumedthattheswitcherisinLock
mode0(fullyunlocked).ThefollowingtwoLock modes are also available:
• Lock mode 1 — All changes are locked from the front panel (except for setting
Lockmode2).Somefunctionscanbeviewed.
• Lock mode 2 — Advanced features are locked and can be viewed only. Basic
functions are unlocked.
N
The switcher is shipped from the factory in Lock mode 2.
See“Settingthefrontpanellocks(Executivemodes)”onpage3-52foradetailedlist
of basic and advanced functions and the procedure to set the various front panel
locks.
Power
Apply power by connecting the power cord to an AC source. The switcher
performs a self-test that flashes the front panel button indicators green, red, and
amber and then turns them off. (The order in which the colors are displayed
dependsonthemodel.)Anerror-freepowerupself-testsequenceleavesallI/O
andcontrolbuttonseitherunlitorshowingbackgroundillumination.Thelit/unlit
status of the RGBHV or Video button and the Audio button is defined by the
system configuration as follows:
• Audio models —RGBHV/VideoandAudiobothlit
• Models without audio —RGBHV/VideolitandAudiounlit
The current configuration and all presets are saved in non-volatile memory. When
power is applied, the most recent configuration is retrieved. The previous presets
remain intact.
Ifanerroroccursduringtheself-test,theswitcherlocksupanddoesnotoperate.
Ifyourswitcherlocksuponpower-up,calltheExtronS
3
Sales&TechnicalSupport
Hotline.