A SERVICE OF

logo

5-3
CrossPoint / MAV Matrix Switchers • Matrix Software
4. Followtheon-screeninstructions.Bydefault,theinstallationoftheMatrix
SwitchersControlProgramcreatesaC:\ProgramFiles\Extron\Matrix_
Switchersdirectory,anditplacesthefollowingfouriconsintoagroupfolder
named“ExtronElectronics\MatrixSwitchers”:
• MATRIXSwitcher+ControlProgram
• MATRIXSwitcher+Help
• UninstallMATRIXSwitcher
• CheckforMatrixUpdates
N
Besides the LAN port, the CrossPoint or MAV switcher can support remote
control via either the rear panel Remote RS-232/RS-422 Remote port or the front
panel Configuration port (matrix sizes up to 1616).
Remote RS-232/RS-422 port — The port can be configured for either the
RS-232 or RS-422 serial communication protocol and operate at 9600, 19200,
38400, or 115200 baud. See “Selecting the rear panel Remote port protocol and
baud rate” in chapter 3, “Operation”, to configure the rear panel port from the
front panel.
Configuration port (matrix sizes up to 1616 only) — The port supports
RS-232 serial communication protocol only. The port can operate at 9600,
19200, 38400, or 115200 baud, but Extron recommends leaving this port
at 9600 baud. See the Serial port configuration commands on page 4-25 to
configure either port using an SIS command.
Software operation via Ethernet
WhenaCrossPointorMAVswitcherisconnectedtoanEthernetWANorLAN,up
to200userscanoperateit,locallyorremotely,usingtheMatrixSwitchersControl
Program.See“Ethernet”inchapter2,“Installation”,forinstallationdetails.
Connection to the switcher via the Ethernet is password protected. There are two
levels of password protection: administrator and user. Administrators have full
accesstoallCrossPointorMAVswitchingcapabilitiesandeditingfunctions.Users
can select inputs and outputs, set and recall presets, and view all settings with
theexceptionofpasswords.Ifthesamepasswordornopasswordisrequiredfor
logging on, all personnel log on with administrator privileges. Fields and functions
thatexceeduserprivilegesaregrayedoutintheMatrixSwitchersControlProgram
when the operator is logged on as a user.
Ethernet protocol settings
TheIPSettings/Optionsscreen(gure5-7onpage5-7)providesalocationfor
viewingand,ifconnectedviatheRS-232linkorifloggedonviatheLANportasan
administrator,editingsettingsuniquetotheEthernetinterface.See“IPSettings/
Optionswindow”,laterinthischapter,formoredetails.