Sterling 682.88107.00 Model Vehicle User Manual


 
Upright Portable Hot Oil TCUs Chapter 7: Appendix 41
Figure 6: Upright Series Hot Oil Portable Temperature Control Unit
Upright Series Temperature Control Unit Specifications
Upright- Model number
1 1.5 2 3
12 kW heater 17 18 19 20
18 kW heater 25 26 27 28
24 kW heater 32 33 34 35
36 kW heater 47 48 49 50
Full load amps; 460/3/60 VAC
48 kW heater 62 63 64 65
Reservoir capacity in gallons / liters 17 gallons each zone c
hp (kW) 1 (0.75) 1.5 (1.1) 2 (1.5) 3 (2.2)
gpm 18 24 50 Flow
lpm 68 91 227
psig 30 50 30/50 50 Pressure
bar 2 3.4 2/5.4 5.4
TEFC pump
Connection size in inches 1” 1.5”
Height 62 (1,575)
Width 24 (610)
Dimensions in inches / (mm)
Depth
34 (864)
< 24 kW
44 (1,118)
> 24 KW
< 24 kW
700 850
Shipping weight in lbs. / Kg
> 24 KW
950 1,050
c Each zone requires 15 gallons minimum to run properly.