GTO 12 Safety Gate User Manual


 
16 GTO 4000XLS Instruction Manual © 01.10.12
1 2 3 4
ON DIP
STATUS
LEARN RMT
LEARN
MAST LIMIT
LEARN
2ND LIMIT
S3
S4
S2
OFF
SOFT START OFF
WARNING OFF
OPEN PULL
2ND OPEN DLY.
MODE1 OFF
MODE2 OFF
ON
ON
PUSH
SIMULT.
ON
ON
120 MIN MAX
AUTO CLOSE TIME STALL FORCE
Auto Close Time
Potentiometer
Adjust the Stall Force Setting
The Stall Force potentiometer on the
control board controls the obstruction
sensitivity (or the amount of force the
operator will apply to an obstruction for
two (2) seconds before it automatically
stops and reverses direction).
IMPORTANT: For safety reasons
the stall force setting will need
to be adjusted for your particular
application.
The Stall Force potentiometer on the
control board operates like a volume
controlonaradio.Useasmallatblade
screwdriver to adjust the potentiometer.
Adjust the stall force from the MIN
position until the gate operates
smoothly without obstructing from its
own weight or wind conditions.
NOTE: you may need to increase the
stall force in cold temperatures due to
increased resistance from gate hinges.
Set Auto Close Time
The Auto-Close Time potentiometer controls the Auto-Close feature, and determines how long the gate
will remain open (at the fully open position) before it begins to close. The settings for this feature are OFF,
or from 3 to 120 seconds.
AdjusttheAuto-Closepotentiometerbyusingasmallatbladescrewdriver.
1 2 3 4
ON DIP
OFF
SOFT START OFF
WARNING OFF
OPEN PULL
2ND OPEN DLY.
MODE1 OFF
MODE2 OFF
ON
ON
PUSH
SIMULT.
ON
ON
120 MIN MAX
AUTO CLOSE TIME STALL FORCE
1 2 3 4
ON
OFF
ON
ON
PUSH
SIMULT.
ON
ON
120 MIN MAX
AUTO CLOSE TIME STALL FORCE
MIN MAX
STALL FORCE