GTO 12 Safety Gate User Manual


 
GTO 4000XLS Instruction Manual © 01.10.12 1
Technical Specications
GTO/ACCESS SYSTEMS 4000XLS AUTOMATIC GATE OPERATOR
DRIVE
• Lowfrictionscrewdrive(linearactuator)ratedfor-5ºFto+160ºF(-21ºCto+71ºC).UseofGTObatteryheaterFM316
(Not solar compatible) is recommended in extreme cold temperatures.
• Poweredbya12Vmotorwithintegralcasehardenedsteelgearreducer.Motorspeedreducedto375rpm.
• Maximumopeningarcof110º.Approximateopeningtime(90º):16-20seconds,dependingonweightofgate.
POWER
• Thesystemispoweredbya12Vdc,7.0Ah,sealed,rechargeableacidbattery.
• Batterychargeismaintainedbya120Vac,18Vacoutputtransformer.Blade-stylecontrolboardfuseisratedfor25A.
NOTE: The transformer should not be directly connected to any battery. Do not replace fuses with higher ampere rated
fuses; doing so will void your warranty and may damage your control board.
• Foroptionalsolarchargingseepage2.
CONTROL
• GTOmicroprocessor-basedcontrolboardissetforpull-to-opengateinstallations.DIPswitchescanbeadjustedto
accommodate an optional kit for push-to-open gates (see Accessory Catalog).
• Acircuitonthecontrolboardregulatescharging.“Sleepdraw”is25mA;“activedraw”is5to9A.
• Auto-memorizationofdigitaltransmittercode.
• GTOremote-mountedRFreceivertunedto318MHz.
• Operatorlengthwithpush-pulltubefullyretractedis46
1
/
4
”, mounting point to mounting point, arm stroke 22” max.
• Minimumgatelengthis6ft.
• Adjustableauto-close(3to120seconds),andstallforcepotentiometers.
• Powerterminalblockaccommodatesatransformerorsolarpanels(notboth).
• DIPswitchessimplifysetupofgateoperator.
• AccessoryterminalblockfullycompatiblewithGTOpushbuttoncontrols,digitalkeypads,loopsdetectors,etc.
• Controlboardallowsconnectionofsafetyedgesensorsandphotoelectricsensors.
• Audioentrapmentalarmsoundsifunitencountersanobstructiontwicewhileopeningorclosing.
OPERATIONAL CAPACITY
• TheGateCapacityChartshowsapproximatecycles,perday,youcanexpectfromthe4000XLSAutomaticGate
Operators when powered with a transformer. Actual cycles may vary slightly depending upon the type and
condition of gate and installation.
NOTE: BALL BEARING HINGES SHOULD BE USED ON ALL GATES WEIGHING OVER 250 LB.
To determine the number of cycles the gate operator will perform using solar panels, please see the specications
listed on page 2.
* An operation cycle is one full opening and closing of the gate.
These specications are subject to change without notice.
Gate Weight
Gate Length
GTO/ACCESS SYSTEMS 4000XLS Gate Capacity Chart
Estimated number of daily cycles, based on use with a transformer and one(1) 12 Volt battery
20 ft.
16 ft.
12 ft.
6 – 10 ft.
135
140
145
150
300 lb.
130
135
140
145
400 lb.
125
130
135
140
500 lb.
120
125
130
135
600 lb.
115
120
125
130
700 lb.
110
115
120
125
800 lb.
105
110
115
120
900 lb.
100
105
110
115
1000 lb.