Graco 309572ZAF Breast Pump User Manual


 
Installation
20 309572ZAF
Connect FTS with a Non-Heated Whip Hose or Remote Mix
Manifold
1. Carefully extend FTS probe (H) into the
hose section from the proportioner. Do not
bend or kink probe. Insert probe in major
volume (resin) side on systems which
are not 1:1 mix ratio.
2. Connect FTS (5) to mating assembly.
3. Connect fluid hoses to FTS.
4. Install one connector (12) between wires.
Refer to page 13 for instructions.
5. Connect hose assembly cable (4) to FTS
cable (part of 5). Slide insulator sleeves (S)
over connection. Leave slack in cables as
stress relief, to prevent cable failure.
6. Connect appropriate ground wire.
7. See Check Hoses for Leaks, page 21.
NOTICE
To prevent damage to probe, do not kink or
excessively bend hose. Do not coil hose
tighter than the minimum bend radius of 3 ft
(0.9 m). Do not subject hose to excessive
weight, impact, or other abuse.
To use 1/2 in. (13 mm) ID fluid hoses,
remove the adapters from the propor-
tioner fluid manifold and install them in
the FTS swivel inlets.
5
S
H
TI2684E
S
4
To Mix Manifold or
non-heated whip
hose
To
Proportioner
12