Page 15
DANIEL
®
SERIES 1500 LIQUID TURBINE FLOW METER SPECIFIC GRAVITY ADJUSTMENTS
S.G. = 1 ( .7 to 1 )
Meter Size Minimum Linear Maximum Linear
BBL/Hr M
3
/Hr USGPM BBL/Hr M
3
/Hr USGPM
1 10 1.59 7 100 15.90 70
1.5 21.4 3.40 15 214 34 150
2 35.7 5.68 25 357 56.76 250
2.5 57.1 9.08 40 571 90.78 400
3* 100 15.9 70 1,000 159 700
4* 185.7 29.52 130 1,850 295 1,295
6* 420 66.77 294 4,192 667.7 2,935
S.G. = 0.5
Meter Size Minimum Linear Maximum Linear
BBL/Hr M
3
/Hr USGPM BBL/Hr M
3
/Hr USGPM
1 22.9 3.64 16 116 36.4 81
1.5 50 7.95 35 246 79.5 172
2 84.3 13.40 59 411 134 288
2.5 134.3 21.35 94 657 213.5 460
3* 235.7 37.47 165 1,150 374.7 805
4* 435.7 69.27 305 2,127 692.7 1,489
6* 988.6 157.2 692 4,830 1,572 3,381
S.G. = 0.3
Meter Size Minimum Linear Maximum Linear
BBL/Hr M
3
/Hr USGPM BBL/Hr M
3
/Hr USGPM
1 32.9 5.23 23 116 52.3 81
1.5 71.4 11.35 50 246 113.5 172
2 118.6 18.56 83 411 185.6 288
2.5 190 32.21 133 657 322.1 460
3* 331.4 52.69 232 1,150 526.9 805
4* 612.8 97.43 429 2,127 974.3 1,489
6* 1,393 221.5 975 4,830 2,215 3,381