SERIES 1200 LIQUID TURBINE FLOW METER DESIGN FEATURES
The following data is applicable for Daniel Series 1200 Liquid Turbine Flow Meter calibrated on mineral spirits.
Size
(Inches)
Standard
Flow Range
Extended
Flow Range
Standard
Flow Range
Extended
Flow Range
Standard
Flow Range
Extended
Flow Range
BBL/Hr BBL/Hr M
3
/Hr M
3
/Hr USGPM USGPM
1 8.6 - 86 99 1.36 - 13.7 15.8 6.0 - 60 69
1.5 18.6 - 186 214 2.96 - 29.6 34 13 - 130 150
2 31.5 - 315 362 50 - 50 57.5 22 - 220 253
3 93 - 930 1.071 14.8 - 148 170 65 - 650 750
4 143 - 1,430 1,785 23 - 230 284 100 - 1,000 1,250
Linearity
Size (Inches) Standard Linearity Premium Linearity
1 +/-0.25% N/A
1.5 +/-0.25% +/-0.15%
2 +/-0.25% +/-0.15%
3 +/-0.15% N/A
4 +/-0.15% N/A
Repeatability: +/-0.02% at any point throughout the minimum to extended maximum ow range.
Nominal K- factor
Size K-factor
(Inches) Pulses/BBL Pulses/M
3
Pulses/US Gal
1 33,600 211,360 800
1.5 16,800 105,680 400
2 7,560 47,556 180
3 2,184 13,877 52
4 966 6,077 23