Dell MD1280 Dollhouse User Manual


 
LED Indicators
6 Gbps SAS I/O module 14 one-color LED status indicators, four each for
the three SAS ports, and two for the module status
Fan module
One single-color LED indicator for module
status
One single-color LED indicator for battery fault
status (not currently used)
One single-color LED indicator for fan fault
status
One single-color LED indicator for power
status
PSU
One singlecolor LED indicator for PSU fault
status
One singlecolor LED indicator for AC fault
status
One singlecolor LED indicator for power status
Power Supply Units (per PSU)
Watt 2.8 kW
Voltage 200–240 VAC (8.6 A–4.3 A)
Heat dissipation 191–147 W
Maximum inrush current Under typical line conditions and over the entire
system ambient operating range, the inrush current
may reach 55 A for each PSU for 10 ms or less.
Available Hard Drive Power (Per Slot)
Supported hard drive power consumption
(continuous)
Up to 1.16 A at +5 V,  Up to 1.6 A at +12 V
I/O Card Power (Per Slot)
Maximum power consumed by I/O Card 11 W at +12 V
Maximum available power 100 W at +12 V
Maximum available power 1 W at +5 V (standby)
Physical
Height 22.23 cm (8.75 inches)
Width 48.26 cm (19 inches)
28