A SERVICE OF

logo

SECTION 3: WIRING AND INSTALLATION DS2100 User's Manual (Preliminary)
PAGE 3-37
3.9.4 D Size DC Bus Inter-connection
Tie screen to chassis via
EMC bracket. See Section 2
L1 L2 L3 PE
(J9.4)(J9.5)(J9.6) (J9.3)
Connector J9
DC+ DC-
(J9.11) (J9.12)
DS2100 D
L1 L2 L3 PE
(J9.4)(J9.5)(J9.6) (J9.3)
DC+ DC-
(J9.11) (J9.12)
DS2100 D
a.c. Mains
L1
L2
L3
Protective
Earth
Connector J9
Figure 3.24 Size D DC Bus Inter-connection
J9
- Fixed connector: 2 pole, screw terminal
- D size wiring: cable 6 AWG (13 mm
2
) for 50/140
- D size wiring: cable 4 AWG ( 21mm
2
) for 60/180
- PE Terminal wiring: cable 6 AWG (13mm
2
) for 50/140
- PE Terminal wiring: cable 4 AWG (21 mm
2
) for 60/180
- Stripping Length 16mm
- Tightening Torque: 2-2.3Nm
Pos.
Name
Function
J9.11 DC+ DC Bus (+)
J9.12 DC- DC Bus (-)
Table 3.12 J9, DC Bus connector, D Size