A SERVICE OF

logo

DS2100 User's Manual (Preliminary) SECTION 3: WIRING AND INSTALLATION
PAGE 3-26
3.7 Three-Phase A.C. Mains Power Source Configuration
The DS2100 may be supplied from a three-phase a.c. mains input. In this case the following user supplied options are
required:-
1. Three-Phase Mains Fusing
2. Mains Line Filter
3. 24Vd.c. Power Source & Fuse
4. 24V d.c. EMC Filter
Note that for DS2100 sizes A,B,C & D, if the a.c. mains is still applied, and the control-backup power is removed, then
the DS2100 control section will still operate correctly. Control power can still be generated from the high voltage D.C.
Bus.
Figure 3.14 below outlines typical interconnect in a multi-axis DS2100 system, which is powered by 3-phase a.c. mains
supply.