A SERVICE OF

logo

12-62 Installation and Maintenance Volume
Octel 200/300 S.4.1 PB6001901
Each disk (software disk for the correct release level, prompt disk, and the
backup configuration disk) must be tested before completing the
remainder of this procedure.
Octel 200/300 prompts
TEST 01 COMPLETE
If any disk fails the test, a replacement must be obtained before continuing
with this procedure. Refer to the Maintenance Commands chapter, Floppy
Disk Drive Diagnostics section, for a description of this diagnostic error.
At the @ prompt enter the slot number for the restored drive. The VCU
software tests the slot and updates its status record.
Repeat DSKTST for each drive to be restored.
@DSKTST B3
CURRENT STATUS
Slot Type ID Status
−−−−−−−−−−−−−−−−−−−−−−−−−−−−−−
B3 System1 S1 Unknown Configured
Test disks
10. Insert a disk into the floppy
drive.
11. @TE F 1
Enter
12. Repeat steps 10 and 11 for each
disk.
Choose the Correct Disk Option
13. Insert disk #3 (for the correct
release level) into the FD.
14. @DSKTST
Enter