S12Q TROUBLESHOOTING GUIDE
SYSTEM STATUS
REMARKS
LAMP
STATUS
(GREEN
LED)
AUDIBLE
ALARM
UV LAMP
ON OFF ON
Correct operating conditions, unit is functioning properly.
OFF ON OFF
The UV lamp is spent, requires replacement lamp.
UV lamp not connected to power source. Check
connection and reconnect lamp.
Ballast has switched off. To reset ballast remove power
to unit by disconnecting power cord from electrical plug
for a minimum of 30 seconds then reapply power.
OFF OFF ON
LED indicator burnt out or wire lead broken. Replace
LED assembly.
S24Q & S40Q TROUBLESHOOTING GUIDE
SYSTEM STATUS
REMARKS
POWER
ON
(RED
LED)
LAMP
STATUS
(GREEN
LED)
AUDIBLE
ALARM
UV LAMP
ON ON OFF ON
Correct operating conditions, unit is functioning properly.
OFF OFF OFF OFF
The unit is not plugged into the electrical outlet. Plug
unit into receptacle and ensure proper power source.
Power not connected to internal components (circuit
board or ballast). Reconnect power connector.
The GFI or one of the cir
cuit breakers is tripped. Re-set
the GFI or circuit breaker
.
ON OFF ON OFF
The UV lamp is spent, r
equir
es r
eplacement lamp.
UV lamp not connected to power sour
ce. Check
connection and reconnect lamp.
Ballast has switched off. To reset ballast remove power
to unit by disconnecting power cord from electrical plug
for a minimum of 30 seconds then reapply power.
ON OFF OFF ON
LED indicator burnt out or circuit board defective. Replace
cir
cuit board.
ON OFF ON ON
Defective cir
cuit board. Contact authorized dealer.