Sterilite S12Q Baby Accessories User Manual


 
5
into existing plumbing (1” for 12 & 24 gpm models). Install “normally-closed” solenoid valve within three (3) feet of
d
isinfection system. Remove the screws on the left and right side of the front aluminum panel allowing this panel to
swing open. Remove the circuit board cover plate to expose the circuit board. Remove the round, black plastic cap
covering the access hole for the solenoid wire (cap located on back panel next to main power cord). Slide the solenoid
power cord (part# CS-MOL) through the hole and affix the connector to the exposed contacts on the circuit board
marked “SOLENOID”. The connector will only slide onto the mating pins in one direction. Attach the ground wire
(
green or green/yellow) to the ground lug on the disinfection system to finish the wiring connections.
T
o complete the installation, push the strain relief into the hole on the backside of the unit. The strain relief allows for
the wire to run through its centre and can easily be installed using pliers. Once all the parts are connected, reattach the
circuit board cover plate and secure the front panel of the disinfection system. Plug the disinfection system into the
electrical outlet to return it to service. Please remember that the unit must have power in order to allow any water to
pass through the unit. If an outside tap is required at all times, including when there may be no power, plumb that line
prior to the solenoid and remember that this line will not be protected from microbiological contaminants. The solenoid
valve will only open when the UV sensor detects adequate UV intensity within the reactor chamber.
Note: If a normally closed solenoid valve is purchased from another source, the use of the manufacturers solenoid cord
is strongly recommended as it comes with the necessary connectors to mate with the circuit board. This cord can be
purchased from a dealer under the part number
CS-MOL.
INFRARED OUTPUT - REMOTE ALARM (Standard on S12Q-GOLD & S24Q-GOLD models)
The electronics incorporated in the monitored units incorporate a micro controller, which operates an infrared (IR)
output. This IR output can be used for diagnostic purposes as well as acting as an interface for an optional remote
audible/visual alar
m package available from your dealer. This IR-ALARM comes with the IR interface and 15.24 meters
(50’) of cable for remote monitoring of the audible and visual signals provided by the UV monitoring mechanism.
THIS ADVANCED WARNING SYSTEM HAS BEEN INSTALLED TO PROVIDE YOU WITH THE
OPTIMUM PRECAUTIONS TO ENSURE HIGH EFFICIENCY IN THE PROTECTION AGAINST
MICROBIOLOGICAL CONTAMINATION IN YOUR WATER. DO NOT DISREGARD THE
WARNING LIGHTS.
THE BEST WAY TO CHECK UV OPERATION IS TO HAVE THE WATER TESTED FOR
BACTERIA BY A RECOGNIZED TESTING AGENCY ON A REGULAR BASIS.
Manufacturer warrants the ultraviolet disinfection system’s hardware and electrical systems to be free from defects in
material and workmanship for a period of five (5) years from the date of purchase by the original owner (consumer) on a
pro-rated basis. Manufacturer warrants the ultraviolet lamps and sensor probes to be free from defects in material and
workmanship for a period of one (1) year and the reactor chamber for a period of seven (7) years. The warrantor will at
its option and expense, either repair or replace such units subject to the following conditions, exceptions, and
exclusions.
CONDITIONS, EXCEPTIONS, AND EXCLUSIONS
The foregoing limited Warranty is subject to the following terms and conditions:
1. W
ater passed thr
ough the unit must fall within the following parameters:
a) Iron: < 0.3 ppm (0.3 mg/L)
b) Hardness*: < 7 gpg (120 mg/L)
c) T
urbidity: < 1 NTU
d) Manganese: < 0.05 ppm (0.05 mg/L)
e) Tannins: < 0.1 ppm (0.3 mg/L)
f) UV Transmittance: > 75% (call factory for recommendations on applications where UVT < 75%)
* Wher
e total hardness is less than 7 gpg, the UV unit should operate efficiently provided the quartz sleeve and/or
sensor probe is cleaned periodically. If total hardness is over 7 gpg, the water should be softened
Warranty will be void, if the proper steps are not taken to ensure that these impurities are not present.
2. This limited Warranty shall not apply to any unit which has been repaired or altered by anyone other than the
Warrantor or by a person authorized by the Warrantor, nor to any units which have been subject to misuse, neglect,
or accident.
3. This limited Warranty runs exclusively to the original Consumer and with respect to the original installation only.
4. WARRANTOR SHALL NOT BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES.
5. This limited Warranty excludes the cost of labour in removing any defective unit or installing any replacement unit.
This limited W
ar
ranty applies only to a unit when returned to the Warrantor at the owner’s expense and in
accor
dance with shipping instr
uctions r
eceived fr
om the W
arrantor.
WARRANTY: