EPX10 User Manual ◄ 13
Lift level tool
P/N-62394
IMPORTANT! The normal liftheight is 2mm / 0.078 in.
This is very important for the arc and energy amount.
Too high liftheight increase the risk of a “coldbrazing”,
too low liftheight reduce the time and increase misres.
1. Insert this end in to the gun.
2. Press and hold “SETTING” and press =”ON/OFF”.
When “LOW BATTERY” is lit, release buttons.
Press “SETTING” and the leds will start to blink.
In this mode the unit is able to check the lift height.
Important! Press the tool completely against the gun then pull the trigger.
Otherwise the gun may be damaged!
Important! Hold the gun so the tool is horizontal.
3. The lift level is calibrated when the inner rod, made of brass, on the tool is in same level as the outer plastic
sleeve. Tolerance ±0,2 mm / 0.007 in. If the gun is not calibrated see seperate instruction for adjusting of the gun.
MAINTENANCE