Monarch 1071-4833-121 Stroller User Manual


 
3
Signal Input
Common
(GND)
Common
(GND)
Signal Input
Figure 4 Output Connector Connection Detail
With no external input, the
output jack (! pointing away
from socket) provides a TTL
compatible pulse from the
strobe’s internal oscillator. If
an external input is applied,
the output pulse mimics the
input pulse delayed by
whatever delay is active. This output pulse may be used to trigger a second stroboscope
synchronously to illuminate larger areas. Many strobes can be “daisy chained”. The output
jack of the strobe is connected to the input jack of the next strobe causing all the strobes to
flash together and be controlled by the first strobe in the chain.
3.0 OPERATION
To turn on the stroboscope, depress and hold the trigger. The trigger may be locked in position
using the side locking button. To lock the trigger on, hold the unit in the right hand, depress the
trigger as far as it will go, and then use your thumb to press the locking button. You can release the
trigger and the trigger will be held in place. To release the trigger lock, simply depress the trigger
and then release.
When the strobe is powered up, it will operate in the last mode selected prior to turn off. The
Phaser-Strobe is shipped from the factory in the Internal mode.
To display the software revision and then do a display test, press and hold the display button and
then depress the trigger to turn on the strobe.
There are four operating modes for the Phaser-Strobe. These are Internal, External, External
Phase Delay, and External Time Delay. All but the Internal mode require an external input signal.
In the Internal mode, the knob adjusts the flash rate from 30 to 32,500 Flashes Per Minute (FPM).
In the External mode, an external signal pulse is used to trigger the flash and the knob has no
effect. In the External Phase Delay mode, the flash is triggered 1 to 359 degrees after each
external signal pulse. The knob sets the amount of delay in degrees. In the External Time Delay
mode, the flash is triggered 0.0005 to 6.5 seconds after each external signal pulse. The knob sets
the amount of delay in seconds.
3.1 Using the Knob
Although the knob on the Phaser-Strobe has an analog style, it is actually a digital encoder
that is connected directly to the microprocessor. The knob has very definite steps or clicks (32
per revolution) allowing very definite adjustment, and it can be turned continuously. This is
equivalent to having a 550-turn potentiometer in an analog unit. Of course you are not expected
to turn the knob 550 times to get from the slowest flash rate to the fastest!
Each time the knob is turned, the blinking digit is either incremented (clockwise) or decremented
(counter-clockwise). There is an automatic roll over to the next digit on the 0 to 9 or 9 to 0
change. It is possible to adjust from the lowest to highest values using a single digit adjustment.
By selecting a different blinking digit, the user can select the step size to increment or decrement
the flash rate (time delay or phase delay) of 0.05, 0.1, 0.5, 1, 10, 100, 1000 and 10,000 per
‘click’. When adjusting the flash rate, choose an increment value that will quickly get you in
the range you want to be, and then select smaller increments to fine tune the value.
NOTE: There are maximum and minimum values in each mode beyond which you cannot
adjust. In the Internal Flash mode, the maximum flash rate is 32,500 FPM. If you
are adjusting the rate in 1000 increments and you reach a value which on the next
10
8.0 BATTERY AND POWER SUPPLY SPECIFICS
8.1 Displaying Battery Charge Percentage
To view the current battery charge percentage, press the DISPLAY button to cycle the display
between FPM, FPS, PHASE, TIME, and the battery charge percentage. The battery charge
percentage will display the current battery charge level from 0 to 100% for about 2 seconds
and then automatically return to FPM. PHASE and TIME are skipped when not in an External
Delay mode.
When the strobe is not flashing, the battery charge percentage represents the percentage of
usable charge left in the batteries. When the strobe is flashing, the percentage value will be
lower. The percentage value will generally decrease with increasing flash rates giving the user
an indication of how much quicker the batteries will be discharged at the current flash rate.
8.2 Low Battery Indication
When the batteries are low, the display blinks “LO BAT” every half second. The strobe may
still be used for a short time. When the battery charge is further depleted, the strobe will stop
flashing, display “LO BAT” and then completely shut off. When “LOW BAT” is displayed, the
unit needs to be recharged (section 8.3 Charging the Batteries) or powered by the power
supply/charger (section 8.4 External Power Supply/Charger).
8.3 Charging the Batteries
The unit may be recharged at any time. You do not need to wait until the low battery condition
is indicated.
CAUTION: Use of power supplies or rechargers other than the one supplied
(R-5, R-6, PSC-3 or PSC-4) may damage the stroboscope and void
the warranty.
To charge the battery with the standard recharger (R-5 or R-6):
1. Release the trigger so the strobe is off.
2. Plug the recharger cable into the recharger socket (located below the display panel
behind the handle).
3. Plug the recharger into an AC mains wall outlet.
The recharger will fast charge the batteries for up to 5 hours (typically 3½ - 4 hours). Once the
fast charge is completed, the recharger will trickle charge the batteries (as indicated by all the
chevrons on the display coming on).
To charge the battery with the external power supply/charger (PSC-3 or PSC-4):
1. Release the trigger so the strobe is off.
2. Plug the power supply/charger cable into the recharger socket (located below the
display panel behind the handle).
3. Plug the power supply/charger into an AC mains wall outlet.
4. Move the switch on the power supply/charger to “CHARGE”. Charging takes
approximately 16 hours.
WARNING: The unit may be left on to charge overnight, but the unit should not
be left on charge indefinitely (more than 36 hours) as this will
damage the lead acid batteries.
8.4 External Power Supply/Charger
The external power supply/charger (PSC-3 or PSC-4) can also be used to run the stroboscope
continuously from the AC mains.