SYMPTOM DIAGNOSIS CHECK:
Status (clear)1 blink Cycle Terminal
Shorted
•Disconnectthepushbutton,keypad,intercomkeypad,or
any other accessory wired to this terminal.
•Trytheremote.Iftheremoteworks,thentheproblemis
the accessory.
Status (clear) 2
blinks
Safety Terminal
Shorted
•Disconnecttheloopdetector,photobeam,oranyother
accessory wired to this terminal.
•Trytheremote.Iftheremoteworks,theproblemisthe
accessory.
Status (clear) 3
blinks
Exit Terminal
Shorted
•Disconnectexitwand,loopdetector,photobeam,orany
other accessory wired to this terminal.
•Tryremote.Iftheremoteworks,theproblemisthe
accessory.
Status (clear) 4
blinks
Shadow Terminal
Shorted
•Disconnecttheloopdetector,photobeam,oranyother
accessory wired to this terminal.
•Tryremote.Iftheremoteworks,theproblemisthe
accessory.
Status (clear) 5
blinks
Close Edge
Terminal Shorted
•Disconnecttheedgesensor,photobeam,oranyother
accessory wired to this terminal.
•Trytheremote.Iftheremoteworks,theproblemisthe
accessory.
Status (clear) 6
blinks
Open Edge
Terminal Shorted
•Disconnectedgesensor,photobeam,oranyother
accessory wired to this terminal.
•Trytheremote.Iftheremoteworks,theproblemisthe
accessory.
RF (yellow) Flickers Receiving 318 MHz
RF
•Normaloperationwhenremoteorwirelesskeypadisused.
RF (yellow)OFF No 318 MHz RF
Received
•BatteryinRemote
•ProgramRemote
•AntennaReceiverConnections
•AntennaReceiver
Power (green)
ON
AC or Solar Power
Present
•NormalOperation
VOLTAGE READINGS
18 Vac Transformer 18.0 to 22.0 Vac
10 W Solar panel (single) 18.0 to 22.0 Vdc
In FULL SUN — measure voltage with the Solar Panel Disconnected.
12 V, 7 amp hour Battery 12.5 to 13.5 Vdc
or Two 12V, 7 amp hour Batteries if using solar power
Measure voltage at battery terminals with battery disconnected
Charging circuit 12.0 to 14.8 Vdc
Measure voltage at battery terminals with battery connected