Graco 311511G Dollhouse User Manual


 
Fluid Circulation
311511G 31
Fluid Circulation
Circulation Through Reactor
To circulate through gun manifold and preheat hose; see
page 32.
1. Load fluid with feed pumps; see page 21.
2. Route circulation lines back to respective
component A or B supply drum. Use hoses rated at
the maximum working pressure of this equipment,
see hose manual.
3. Set RECIRC/SPRAY valves (SA, SB) to RECIRC.
4. Turn Main Disconnect Switch (R) ON.
5. Open air inlet ball valve.
6. Set temperature targets; see page 22. Turn on
heater.
7. Set both Air Regulator pressures to start at 15 psi
(1.0 bar).
8. Turn PARK/RUN switch to RUN.
9. Turn Pump Mode Function switch to START.
10. Recirculate until desired temperature reaches set
point.
11. Turn Pump Mode Function knob to OFF.
12. Turn on hose heat if hose is filled with fluid without
air pockets or solvent.
13. Set PRESSURE RELIEF/SPRAY valves (SA, SB) to
SPRAY.
Read Warnings; see page 4. Do not circulate fluid
containing a blowing agent without consulting with
your material supplier regarding fluid temperature
limits.
Do not install shutoffs downstream of the PRESSURE
RELIEF/SPRAY valve outlets (BA, BB). The valves
function as overpressure relief valves when set to
SPRAY. Lines must be open so valves can
automatically relive pressure when machine is
operating.
SB
SA
BB
BA
ti8442a
Do not turn on hose heat unless hoses are already
loaded with fluid.
For additional circulation information, refer to
manual 309852.
ti8442a
SA
SB