Two Serial Servers are connected to a network, one configured as a TCP or
UDP client and the other as a TCP/UDP server. When setting up the server
the remote IP address section must contain the address of the client. This will
allow the client’s IP address to pass the IP address-filtering feature of the
server. Conversely, the Remote IP address of the client must contain the
server’s IP address. Both communication port numbers must be the same.
Heart Beat
The Heart Beat protocol connection provides a reliable communications
connection in
Virtual COM Port Mode or with Paired Connection Mode.
This feature restores the connection if communications are temporarily lost at
either end due to loss of power or Ethernet connection.
Without this feature a device that loses a connection and stops
communicating would not be able to reconnect without human intervention.
A TCP data connection can be lost when there is a power failure or
temporary loss of an Ethernet connection on either the client or server. If a
loss occurs the Heart Beat feature will try to reconnect the TCP data
connection every five seconds until communications is established again. The
Heart Beat feature is available for use in
Virtual COM Port Mode and Paired
Connection Mode. This is not available when using a UDP application.