![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/8/fc/8fc8eead-9d11-4858-a3a8-ae451a4ca11c/8fc8eead-9d11-4858-a3a8-ae451a4ca11c-bgd.png)
GR60 User Manual ◄ 13
If symptoms of poor performance develop, the following chart can be used as a guide to correct the problem.
When diagnosing faults in operation of the grinder, always check that the hydraulic power source is supplying the
correct hydraulic ow and pressure to the grinder as listed in the table. Use a owmeter known to be accurate.
Check the ow with the hydraulic oil temperature at least 80°F/27°C.
Grinder does not run Hydraulic power source not Check power source for proper
functioning. owandpressure(7-10gpm/
26-38lpm@1500-2000psi/
105-140bar.
Couplersorhosesblocked. Locateandremoverestriction.
Hydraulicmotorfailure. Inspectandrepair.
Hydraulic lines not connected. Connect lines.
Grinderoperatestooslow. Hydraulicmotorspeedtoslow. Checkpowerunitforproper
ow(7-10gpm/26-38lpm).
Highbackpressure. Checkhydraulicsystemfor
excessiveback-pressure(over
250psi/17bar).
Couplersorhosesblocked. Locateandremoverestriction.
Oiltoohot(above140°F/60°C) Checkhydraulicpowersource
ortoocold(below60°F/16°C). forproperoiltemperature.
Bypasscoolertowarmoilor
providecoolertomaintain
propertemperature.
Reliefvalvesettoolow. Adjustreliefvalveto2100-2250
psi/145-155bar.
Hydraulicmotorworn. Inspect,repairorreplace.
Flowcontrolmalfunctioning. Haveowcontrolservicedat
anauthorizedStanleyservice
center.
Grinderoperatestoofast. Flowcontrolmalfunctioning. Haveowcontrolandvalve
bodyservicedatanauthorized
Stanleyservicecenter.
TROUBLESHOOTING