Choosing the Installation Location
Avoid the following places to prevent malfunction of the unit
- Where there is machine oil - Salty environment such as the seaside areas
- Where sulfide gas exists - Other special atmosphere areas
CAUTION
Indoor Unit Outdoor Unit
Where airflow is not blocked
Where cool air can be distributed throughout the room
Install the refrigerant piping length and the height
difference of both indoor and outdoor units as
indicated in the installation diagram
Wall that prevents vibration and is strong enough to hold the
product weight
Out of the direct sunlight
3.3ft (1m) or more away from the TV or radio
(to prevent the screen from being distorted or noise from being
generated)
As far away as possible from fluorescent and incandescent lights
(so that the remote control can be operated well)
A place where the air filter can be replaced easily
Where it is not exposed to strong wind
Well ventilated and dustless places
Out of the direct sunlight and rain
Where neighbors are not annoyed by operation sound or hot air
Solid wall or support that prevents vibration and is strong
enough to hold the product weight
Where there is no risk of flammable gas leakage
When installing the unit at a high place be sure to fix the unit
legs
9.9ft (3m) or more away from the TV or radio (to prevent the
screen from being distorted or noise from being generated)
Install the unit horizontally
PREPARING FOR INSTALLATION
Observe the clearances and maximum lengths as seen in the picture below when installing the air conditioner.
4.9 inch (125mm)
or more
11.8 inch (300mm) or more
4.9 inch (125mm)
or more
23.6 inch (600mm)
minimum
11.8 inch (300mm)
minimum
Wrap the refrigerant pipes and the drain
hose with the absorbent pad and vinyl
tape. Refer to page 15 for further details.
You can select the direction
of draining. (left or right)
The appearance of the unit may be different from the diagram depending on the model.
23.6 inch (600mm)
minimum
11.8 inch (300mm)
minimum
“A” maximum
total pipe length
“B” maximum total
pipe Height
Model “A” “B”
AQV09J
AQV12J
49.2ft(15m) 26.2ft(8m)
AQV18J
AQV24J
98.4ft(30m) 49.2ft(15m)