8 Maintenance and Repairs Monitoring
© 2007 Moog GmbH User Manual RKP-II (CA53461-001; Version 1.0, 10/07) 53
8 Maintenance and Repairs
Maintenance and Repairs
8.1 Monitoring
Monitoring
For pumps in explosive areas, the supplementary documentation should
also be observed:
Ö User Manual RKP II Explosion-proof
For any and all tasks to be performed on the pump, suitable personal
protective equipment should be worn.
Ö Chap. "2.2.4 Work Safety", Page 9
Tasks Intervals
Check pump for leakage Daily
Check pump for noises Daily
Check that fasteners are tightened Monthly
Check the machine's operating temperature
at constant operating conditions
Weekly
Check the machine's operating fluid level Daily
Check the operating fluid quality Annually or every 2000
operating hours
Tab. 15: Monitoring