![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/d/5b/d5b804fd-992e-40cc-81a0-7da3c32a6187/d5b804fd-992e-40cc-81a0-7da3c32a6187-bg2a.png)
Installing the Pump 6 Mounting
34 User Manual RKP-II (CA53461-001; Version 1.0, 10/07) © 2007 Moog GmbH
6.2 Installing the Pump
Installing the Pump
Pre-Conditions:
• Mounting area is freely accessible.
• Machine / equipment is at zero pressure and idle.
• Operation fluid matches the information on the order data sheet.
• Standard tools and mounting material are at hand.
• Supplementary documentation is available.
• The specified rotation of the pump corresponds with the drive motor.
WARNING Risk of Crushing!
During mounting, the pump may topple over and crush body
parts.
• Select lifting tackle to correspond with the overall weight
of the pump.
• Attach the lifting tackle to the pump properly.
Ö Chap. "5.2 Transporting the Pump", Page 29
• Avoid all areas below the floating load.
WARNING Risk of injury and poisoning by dangerous operating fluid!
Leaks from dangerous operating fluid may lead to serious
injuries.
• Check to ensure that the operating fluid in use does not
pose a risk.
• Make sure that the machine / equipment is at zero
pressure and idle.
• Wear protective work equipment such as, e. g., work
gloves. Ö Chap. "2.2.4 Work Safety", Page 9
DANGER Risk of Death by Electrocution!
Contact with hot parts may lead to severe injuries and even
death.
• Make sure that the machine / equipment is idle.
CAUTION Damage to Property from Soiling!
Removing end caps to the pump connections may lead to
soiling and as a result property damage.
• Do not remove end caps until shortly before mounting.
WARNING Risk of injury and property damage as a result of
vibration!
Vibrations from machines / equipment parts may lead to bodily
injury or property damage.
• Uncouple the pump using suitable antivibration elements.
The pump's mounting position is optional.