DEFINITY Enterprise Communication Server Release 9
Getting Started with the Avaya R300 Remote Office Communicator
Issue 1
November 2000
Avaya R300 Administration
88Resetting the Avaya R300
5
When you upload this remote configuration information, keep in mind the following:
■ The Avaya R300 reads Dialout-Framed-User entries with the password ascend.
■ The Upd Rem Cfg command does not update the terminal-server banner or list of
Telnet hosts if the Remote Conf parameter is set to No.
■ If the Ascend-Authen-Alias attribute is defined in RADIUS, the Upd Rem Cfg
command also updates the Avaya R300 system name used when establishing PPP
calls.
NOTE:
In some cases, you might wish to update the Avaya R300 unit’s routing
tables when connecting to a user whose profile includes
Service-Type=Framed. In this case, set the Framed-Route attribute in
an incoming user profile to specify the user’s IP address and subnet mask in
the host_ipaddr and subnet_mask arguments. The route you specify
in this manner exists only during the time the call is online. When you enter
a nonzero router address for router_ipaddr and it is different from the
caller’s address, the static route of a dial-in frame persists even after the
connection goes offline.
Example: This example shows two RADIUS pseudo-user profiles defining global static IP routes:
route-1 Password=ascend Service-Type=Outbound
Framed-Route=10.0.200.33/29 10.0.200.37 1 n lala-gw-out
Framed-Route=10.0.200.50/29 10.0.200.37 1 n lala-gw-out
Framed-Route=10.0.200.47/29 10.0.200.49 1 n nana-gw-out
route-2 Password=ascend Service-Type=Outbound
Framed-Route=11.0.200.33/29 11.0.200.37 1 n zzz-gw-out
Framed-Route=12.0.200.47/29 11.0.200.49 1 n kk-gw-out
Resetting the Avaya R300
The Avaya R300 unit needs to be reset if you upload a new system software configuration
(not a new Avaya R300 profile configuration). You can reset the Avaya R300 unit in one
of the following ways:
■ Choose System >Sys Diag > Sys Rest from the VT100 menu interface.
■ Type reset at the diagnostic prompt.
■ Power cycle the unit by pulling the plug out of the outlet and then plugging it back
into the outlet.
NOTE:
Power cycling is not the preferred method of shutting down the Avaya R300.
The system does some clean-up with DEFINITY when reset using one of
the other methods.