Pride Mobility Quantum 614 High Chair User Manual


 
34 www.quantumrehab.com Quantum 614 Series
VII. CARE AND MAINTENANCE
The body shroud has been sprayed with a clear sealant coating. You can apply a light coat of car wax to help it retain
its high-gloss appearance.
Check all electrical connections. Make sure they are tight and are not corroded. Batteries must sit flat within the battery tray,
with the battery terminals facing inward, toward each other. Refer to the battery wiring label for the correct wiring layout.
WARNING! Even though the power chair has passed the necessary testing requirements
for ingress of liquids, you should keep electrical connections away from sources of
dampness, including direct exposure to water or bodily fluids and incontinence. Check
electrical components frequently for signs of corrosion and replace as necessary.
Daily Checks
With the controller turned off, check the joystick. Make sure it is not bent or damaged and that it returns to the neutral
position when you release it. Check the rubber boot around the base of the joystick for damage. Visually inspect the
boot. Do not handle or try to repair it. See your Quantum Rehab Provider if there is a problem.
Visually inspect the controller cable. Make sure that it is not frayed, cut, or has any wires exposed. See your Quantum
Rehab Provider if there is a problem.
Check for flat spots on solid tires. Flat spots could adversely affect stability.
Inspect the armrests for loose hardware, stress points, or damage. See your Quantum Rehab Provider if there is a problem.
Weekly Checks
Disconnect and inspect the controller from the power base. Look for corrosion. Contact your Quantum Rehab Pro-
vider if necessary.
Ensure that all parts of the controller system are securely fastened to your power chair. Do not overtighten any screws.
Check for proper tire inflation. Maintain but do not exceed the psi/bar/kPa air pressure rating indicated on each tire. If
a tire does not hold air, see an Quantum Rehab Provider for replacement of the tube.
Calibrate the joystick if a noticeable difference in performance is detected or if the joystick does not operate properly.
To calibrate the joystick, power off the unit, place the joystick in the neutral position, and power the unit back on. If a
problem still exists with your joystick’s performance, contact your Quantum Rehab Provider.
Check the brakes. This test should be carried out on a level surface with at least three feet (1 meter) of clearance
around your power chair.
To check the brakes:
1. Turn on the controller and turn down the speed level of your power chair.
2. After one second, check the battery condition meter. Make sure that it remains on.
3. Slowly push the joystick forward until you hear the electric brakes click. Immediately release the joystick. You must be
able to hear each electrical brake operating within a few seconds of joystick movement. Repeat this test three times,
pushing the joystick backwards, then left, and then right.
Monthly Checks
Check for drive tire wear. See your Quantum Rehab Provider for repair.
Check the caster wheels for wear. Replace them as necessary.
Check the caster forks for damage or fluttering which indicates that they may need to be adjusted or have the bearings
replaced. See your Quantum Rehab Provider for repair.
Keep your power chair clean and free of foreign material, such as mud, dirt, hair, food, drink, etc.
Yearly Checks
Take your power chair to your Quantum Rehab Provider for yearly maintenance, especially if you use your power chair on
a daily basis. This helps ensure that your power chair is functioning properly and helps prevent future complications.