5.
Using the Manual Breast Pump
with the AVENT Feeding Bottle
Simply replace the VIA Cup and Adaptor with the AVENT
Feeding Bottle. To make the pump completely stable
insert the bottle into the funnel cover (a).
6. How to assemble the Manual
Breast Pump
Separate all parts and ensure pump has been cleaned
and sterilised as in section 3:
1) Wash your hands thoroughly. Insert the white valve (g) into the
pump body (f) from underneath.
2)
Place the pump body (f) onto the VIA Adaptor (h). Twist gently clockwise
until secure.
DO NOT OVERTIGHTEN !
3)
Place the assembled pump body and VIA Adaptor onto the VIA
Cup (i). Twist gently clockwise until secure.
DO NOT OVERTIGHTEN !
4)
Place the silicone diaphragm with stem (d) into the pump body (f). Make
sure it fits securely around the rim by pressing down with
your fingers to ensure a perfect seal. (This is easier if assembled
whilst wet.)
5)
Place the forked end of the handle (e) under the diaphragm stem
(d) and push down gently on the handle until it clicks into place.
6)
Carefully insert the Let-down Massage Cushion (b) into the pump funnel
(f) making sure it is perfectly sealed all round the rim of
the funnel. (This is easier if assembled whilst wet.)
7) Click the pump cover (c) onto the pump body (f). To make the pump
completely stable, insert the VIA Cup into the VIA Lid/Stand (j).
VIA Feeding System
h) VIA Adaptor
i) VIA Cup (180ml/6oz)
j) VIA Lid/Stand
k) Dome cap
l) Extra Soft Teat, Newborn Flow (0m+)
m) Screw ring
n) Sealing base
*spares included