Linear SWR Safety Gate User Manual


 
SWR SWC SWD Swing Gate Operator Installation Guide - 19 - 227965 Revision X13 3-28-2008
Safety Edge Layout Illustration
RECEIVER INSIDE
GATE OPERATOR
GATE EDGE
TRANSMITTER
SEPARATE PEDESTRIAN
GATE REQUIRED
7FT. MINIMUM DISTANCE
AWAY FROM GATE
EDGE MOUNTED ON
LEADING OUTSIDE EDGE
OF GATE
EDGES MOUNTED ACROSS
BOTTOM OF GATE
WIRE EDGES SHOWN TO THE CLOSE OBSTRUCTION INPUT ONLY
ITEM DESCRIPTION
1 GATE (REFERENCE ONLY)
2 EDGE
3 EDGE EXTRUSION
4 SPACERS (3)
5 8-32 X 1" SCREWS (3)
6 RETAINING BRACKET
REVERSING EDGE
ASSEMBLY CLOSE-UP
5
1
2
3
4
6
WARNING
One or more contact sensors shall be located on the
inside and outside leading edge of a swing gate.
Additionally, if the bottom edge of a swing gate is
greater than six inches (152 mm) above the ground
at any point in its arc of travel, one or more contact
sensors shall be located on the bottom edge.
A hardwired contact sensor shall be located and its
wiring arranged so that the communication between
the sensor and the gate operator is not subjected to
mechanical damage.
A wireless contact sensor such as one that transmits
radio frequency (RF) signals to the gate operator for
entrapment protection functions shall be located where
the transmission of the signals are not obstructed or
impeded by building structures, natural landscaping
or similar obstruction. A wireless contact sensor shall
function under the intended end-use conditions.