SWR SWC SWD Swing Gate Operator Installation Guide - 13 - 227965 Revision X13 3-28-2008
Basic Controller Programming (Cont.)
Run Alarm and Pre-start Alarm
The factory default is Run Alarm on and a 3-second Pre-start Alarm. The
operator’s beeper will sound 3 seconds before the operator starts. The
options are:
Run Alarm Off and Pre-start Alarm Off
Run Alarm On and Pre-start Alarm Off
Run Alarm On and Pre-start Alarm On for 3-9 Seconds
Maximum Open Direction Current Setting
To detect obstacles or mechanical problems with the gate, the operator
monitors its motor current. If the open current load exceeds the
programmed maximum load number, the operator will stop, reverse a
short distance, then stop again. The Auto Close Timer will be disabled,
and another open request will be required to start the operator again. If
after restart, the overload or an open obstacle happens again before the
open limit is reached, the operator will lockout and sound the alarm.
To measure the motor load used during opening, while this function is
being displayed, push and hold the OPEN button to open the gate. The
motor current will be displayed as a load number from 0 to 99. Set the
programmed load number above the measured load number, so that a
minimal force (50-75 lbs.) will activate a reversal should an obstruction
occur, but high enough to keep the gate moving under normal conditions
without interruption.
Maximum Close Direction Current Setting
To detect obstacles or mechanical problems with the gate, the operator
monitors its motor current. If the close current load exceeds the
programmed maximum load number, the operator will stop, reverse a
short distance, then stop again. Another close request will be required to
start the operator again. If after restart, the overload or a close obstacle
happens again before the close limit is reached, the operator will lockout
and sound the alarm.
To measure the motor load used during closing, while this function is
being displayed, push and hold the CLOSE button to close the gate.
The motor current will be displayed as a load number from 0 to 99. Set
the programmed load number above the measured load number, so that
a minimal force (50-75 lbs.) will activate a reversal should an obstruction
occur, but high enough to keep the gate moving under normal conditions
without interruption.
FUNCTION
PRESS ENTER FOR 1 SECOND
WHILE DISPLAY IS FLASHING, PRESS
UP TO SET A LOAD NUMBER ABOVE
THE MEASURED LOAD NUMBER
OPTIONS
MAX CLOSE
CURRENT
PRESS AND HOLD THE CLOSE BUTTON TO
CYCLE THE OPERATOR CLOSED, THE
DISPLAY WILL SHOW THE MEASURED
LOAD NUMBER
ENTER
ENTER
PRESS ENTER TO STORE THE VALUE
"CC"
FUNCTION
PRESS ENTER FOR 1 SECOND
WHILE DISPLAY IS FLASHING, PRESS
UP TO SET A LOAD NUMBER ABOVE
THE MEASURED LOAD NUMBER
OPTIONS
MAX OPEN
CURRENT
PRESS AND HOLD THE OPEN BUTTON TO
CYCLE THE OPERATOR OPEN, THE DISPLAY
WILL SHOW THE MEASURED LOAD NUMBER
ENTER
ENTER
PRESS ENTER TO STORE THE VALUE
"OC"
FUNCTION
RUN ALARM ON
PRE-START ALARM OFF
RUN ALARM ON
PRE-START ALARM ON FOR 3 - 9 SECONDS
OPTIONS
RUN ALARM
PRE-START ALARM
PRESS UP OR
DOWN TO CYCLE
THROUGH OPTIONS
PRESS ENTER TO
SELECT AN OPTION
RUN ALARM OFF
PRE-START ALARM OFF
"RP"