16
Program Switches
OFF ON
1 TIMER TO CLOSE Gate does not automatically close. Gate automatically closes.
2 TIMER TO CLOSE OPT. Gate automatically closes from Gate automatically closes only when completely
any position after opening. open (open limit engaged).
3 SLAVE DISABLE Enables slave side (dual gate use). Disables slave side. (single gate use)
4 SIREN DELAY Siren (optional) active when gate is Siren (optional) starts 5 seconds before gate moves.
moving.
5 ‘STOP’ CIRCUIT ENABLE Must hold down open or close Normal operation
buttons to move gate. Gate stops Momentary open or close input runs gate to limit.
when button released.
6 LOCK TYPE For 12V mechanical (solenoid) locks. For 12V magnetic locks.
(+12V for 4 seconds on open cycle) (+12V when on close limit)
7 COAST ENABLE Gate will stop immediately when at Gate will coast (minimally) when it reaches limits.
Open or Close limit Recommended for 7500 slide operator only.
8 FREE EXIT OPT. A free exit input will open gate from A free exit input will open gate from any
closed position or after a close cycle position after an open or close cycle.
only.
9 DUAL GATE SYNC Both gates operate at normal This feature will control the master gate to open
Speed (slave slower than or close at the same speed as the slave gate.
Master).
10 SMART ACT. Off for 416E & 416EX actuators, Used for 816E & 816EX actuators only
slide gates, 3500 or when slow down (soft start & stop).
feature is not desired.