Aiphone GW-LE8 Baby Monitor User Manual


 
Pg. 4
GW-4P
1
2
3
4
RY-PA
~
~
AC Power
Door Strike
BlkYel
GW-LE8
+
-
PS-12C
GW-LE8 WITH GW-4P, USING LEF-3L MASTER STATIONS WITH COMMON AND INDIVIDUAL DOOR STATIONS
NOTES:
1. Remove D+/D- jumper on all masters.
2. Only components of the entrance panel that include wire connections are shown here.
3. For complete wiring information, please see the standard LEF instructions.
If additional master stations are to be installed in each office/suite, wire them per the standard instructions.
WIRING DIAGRAM:
LEF-3L #1
1
2
E
+
-
R
K2
L
K1
1
E
-
LE-D
To Indv. Door
Strike &
Power
RY-PA
BlkYel
LEF-3L #2
1
E
-
LE-D
To Indv. Door
Strike &
Power
RY-PA
BlkYel
LEF-3L #3
1
E
-
LE-D
To Indv. Door
Strike &
Power
RY-PA
BlkYel
LEF-3L #4
1
E
-
LE-D
To Indv. Door
Strike &
Power
RY-PA
BlkYel
Yel
Blu
Blu
Blu
Blu
Blu
Blu
Blu
Blu
D+
D-
1
2
E
+
-
R
K2
L
K1
1
2
E
+
-
R
K2
L
K1
1
2
E
+
-
R
K2
L
K1