COMMAND
1
DESCRIPTION RESPONSE
ACI3 * Set to 1200 baud rate, default setting [OK]
ACI4 * Set to 2400 baud rate [OK]
ACI5 * Set to 4800 baud rate [OK]
ACI6 * Set to 9600 baud rate [OK]
ACI7 * Set to 19200 baud rate [OK]
CALLs Recall configuration from SETUPs
s: 1 byte ASCII code, ranges from 1 - 8
[OK]
SAVEs Save current configuration to SETUPs
s: 1 byte ASCII code, ranges from 1 - 8
[OK]
SAVE0 Save Global setting(s) [OK]
PTgOmmInn Execute a switch. Connect Input nn to Output mm for Group g.
g: Group #, a 1 byte ASCII code, ranges from 1 - 6
nn: Input #, a 2 byte ASCII code. If nn = 00, no input is selected,
resulting in a blank output.
mm: Output #, a 2 byte ASCII code
Exp: "[PT1O08I04]"
Connect Input #4 to Output #8 for the boards in Group 1
[OK]
Lgo
1
o
2
o
3
. . . Load a new path for Group g. The switch is not executed until the "[SW]"
command is sent.
o
n
: 2 byte ASCII code representing the Input# to be connected to output
#n.
Exp1: "[L104050003]
Load a new path for Group #1 as follows: Input #4 to Output #1, Input
#5 to Output #2, Input #0 to Output #3 (disconnect), and Input #3 to
Output #4.
Exp2: "[L1020101,L2101107]"
Load a new path for Group #1 as follows: Input #2 to Output #1, Input
#1 to Output #2, Input #1 to Output #3.
Load a new path for Group #2 as follows: Input #10 to Output #1,
Input #11 to Output #2, Input #7 to Output #3
[OK]
SW Execute all switch connections as defined by the L command. [OK]
RGBx.x Set RGB delay to x.x seconds. x.x: ranges from 0.0 to 6.5 in 0.5 second
intervals.
Exp: "[RGB3.5]" Set RGB delay to 3.5 seconds.
Note: Normally, the RGB delay is only used when boards 1, 2, 3 & 4 are all
in the same group. However, the RS-232 command sets the unit so that it
ignores this fact. Therefore, if you do not assign boards 1, 2, 3 & 4 to the
same group, you MUST set the RGB delay to 0.0 seconds to ensure proper
switching (with no delays.)
[OK]
GgBb
1
b
2
b
3
. . . Set boards b
1,
b
2,
b
3
. . . to group g
Exp: "[G1B1234]" Define Group 1 as boards 1, 2, 3 & 4
[OK]
IOgOoIi Set input/output configuration for group g
Exp: "[IO1O04I12]" Define Group 1 input/output configuration as 4
outputs and 12 inputs.
[OK]
FP * Enable and disable the front panel operation (toggle between FP0 and FP1. [OK]
FP0 * Disable the front panel operation (put the unit into the Stand-by mode). All
front panel buttons are disabled, except for the Stand-by button, and the
backlight of the LCD screen is turned off.
[OK]
COMMAND
1
DESCRIPTION RESPONSE
1
Leading and ending codes not shown for clarity.
* Global Settings (Save with SAVE0 Command)