Installation Guide
14
69-2486—03
Special functions
Auto Changeover(SetupFunction0300):WhensettoAuto,thethermostatautomaticallyselects
heating or cooling depending on the indoor temperature. Heat and cool settings must be at least 2
degrees apart.
Adaptive Intelligent Recovery (Setup Function 0530): Allows the thermostat to “learn” how long
the furnace and air conditioner take to reach programmed temperature settings, so the temperature is
reached at the scheduled time.
Compressor Protection (Setup Function 0580): Forces the compressor to wait a few minutes before
restarting,topreventdamage.Duringthistime,themessage“Wait”isonthedisplay.
TheTHP9045WiringModuleisdesignedtobeusedwithapplicablethermostatsin1Heat/1
Cool retrofit applications where only 4 wires are available. The K terminal on the thermostat can
be used to operate both the fan and compressor on a single wire, and the module is designed to
receive the signal from the K terminal, split that signal and reroute it to operate the compressor,
and/or fan for normal operation. See the THP9045 manual for further details.
Optional THP9045 Wiring Module
Temperature Ranges
• Heat:40°to90°F(4.5°to32°C)
• Cool:50°to99°F(10°to37°C)
Operating Ambient Temperature
• 0°to120°F(-18°to48.9°C)
Shipping Temperature
• -30°to150°F(-34°to66°C)
Operating Relative Humidity
• 5%to90%(non-condensing)
Physical Dimensions
• 4-23/25”Hx6-2/5”Wx1-19/46”D
• 125mmHx166mmWx36mmD
Electrical Ratings
Terminal Voltage(50/60Hz) RunningCurrent
WHeating 20-30Vac 0.02-1.0A
(Powerpile) 750mVDC 100mADC
W2Heating 20-30Vac 0.02-0.6A
YCooling 20-30Vac 0.02-1.0A
Y2Cooling 20-30Vac 0.02-0.6 A
AuxAuxiliaryheat 20-30Vac 0.02-1.0A
O/BChangeover 20-30Vac 0.02-0.6A
EEmergencyheat 20-30Vac 0.02-1.0A
LHeatpumpreset 20-30Vac 0.02-0.6A
Specifications
Please contact your distributor to order replacement parts.
Cover plate* ............................................................Part Number 32003796-001
*(Use to cover marks left by old thermostats.)
Accessories & replacement parts