![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/8/d8/8d855ba8-f7fc-42e0-9bc3-c57cc8228e02/8d855ba8-f7fc-42e0-9bc3-c57cc8228e02-bg72.png)
4-7CrossPoint 450 Plus and MAV Plus Switchers • Programmer’s Guide
Command/Response Table for SIS Commands
Symbol Definitions:
= Carriage return/line feed
= Carriage return (no line feed)
• = Space
Esc
= Escape key
Input and output numbers in commands may be entered as either 1-digit, 2-digit, or 3-digit
numbers. All input and output numbers are reported as 2-digit numbers in the response.
X
= Input number 01 – (maximum number of inputs for your model)
X
= Input number (for tie)
00 – (maximum number of inputs) (00 = untied)
X
= Output number 01 – (maximum number of outputs for your model)
X
= Numeric dB value –18 to +24 (45 steps of gain or attenuation)
X
= Audio gain 0 – 24 (1 dB/step)
X
= Audio attenuation 1 – 18 (1 dB/step)
X
= Volume adjustment range 0 – 64 (1 dB/step except for 0-to-1, which is 13 dB)
X
= Room # (for room presets) 10 max. (each can have up to 10 presets (
X12
s) assigned)
A Room is a subset of operator-selec ted outputs that relate to each other. The CrossPoint 450 Plus
or MAV Plus switcher supports up to 10 rooms, each of which can consist of from 1 to 16 outputs
.
X
= Mute, Lock mode, power supply
(0 = off/mode 0/not Ok, 1 = on/mode 1/Ok, 2 = mode 2)
X10
= Group # (for I/O grouping) 1 through 4 groups (0 = no group)
X11
= Global preset # 0, 01-32 maximum (0 = current configuration)
X12
= Room preset # 10 maximum (0 = current configuration for room)
A Room preset is a stored configuration with all of the outputs assigned to a single room.
When a room preset is retrieved from memory, it becomes the current configuration.
X13
= RGB delay interval Delay in ½ second increments (10 maximum)
X14
= Video/audio mute: 0 = no mutes
1 = video mute
2 = audio mute
3 = video and audio mute
X15
= Sync frequency xxx.xx (frequency in Hz (V) or kHz (H))
X16
= Connection status 0 = no input connected
1 = input connected
X17
= Firmware version number to second decimal place (x.xx)
X18
= Verbose firmware version-description-upload date/time. See page 4-16.
X19
= Name 12 characters maximum for input, output, global preset,
and room preset names.
11 characters maximum for room names.
Upper- and lower-case alphanumeric characters and
_ / and spaces are valid.
The following characters are invalid in the name: {space} ~ , @ = ‘ [ ] { } < > ’ “ ; : | \ and ?.
X20
= Voltage Positive or negative voltage and magnitude
X21
= Temperature Degrees Fahrenheit
X22
= Fan speed RPM