1.4. Model Names
Agilent Technologies Inc. acquired Acqiris SA and its product lines in December 2006. Use the tables below to cross
reference new Agilent numbers with options to the legacy model name. The legacy model name is what is used in the
Acqiris applications and the API.
Agilent Model Number Acqiris Model Name Agilent Model Number Acqiris Model Name
U1061A-001-F50 DC135 U1091A DC110
U1061A-001-FHZ DC13HZ U1061A-001-F50 DC135
U1061A-002-F50 DC140 U1061A-001-FHZ DC135HZ
U1061A-002-FHZ DC140HZ U1061A-002-F50 DC140
U1063A-001 DC265 U1061A-002-FHZ DC140HZ
U1063A-002 DC270 U1064A-001-F50 DC211
U1064A-001-F50 DC211 U1064A-001-FHZ DC211A
U1064A-001-FHZ DC211A U1064A-002-F50 DC241
U1064A-002-F50 DC241 U1064A-002-FHZ DC241A
U1064A-002-FHZ DC241A U1063A-001 DC265
U1064A-004-F50 DC271 U1063A-002 DC270
U1064A-004-FHZ DC271A U1064A-004-F50 DC271
U1067A DP110 U1064A-004-FHZ DC271A
U1067A DP105 U1067A DP105
U1068A DP210 U1091A DP106
U1068A DP211 U1067A DP110
U1069A DP240 U1068A DP210
U1069A DP235 U1068A DP211
U1069A DP214 U1091A DP212
U1071A-001-F50 DP1400 U1069A DP214
U1071A-001-FHZ U1071AHZ1 U1069A DP235
U1071A-002-F50 U1071A002 U1069A DP240
U1071A-002-FHZ U1071AHZ2 U1071A DP1400
U1071A-004-F50 U1071A004 U1071A-002-F50 U1071A002
U1071A-004-FHZ U1071AHZ4 U1071A-004-F50 U1071A004
U1091A DC110 U1071A-001-FHZ U1071AHZ1
U1091A DP106 U1071A-002-FHZ U1071AHZ2
U1091A DP212 U1071A-004-FHZ U1071AHZ4
1.5. Disclaimer and Safety
The DP Series PCI digitizer cards have been designed to operate in a standard PCI slot found inside most personal
computers. The model DC Series CompactPCI/PXI digitizers have been designed to operate inside a
CompactPCI/PXI crate. The crate provides the modules with all needed power. Agilent does not recommend
operation of the DC Series modules outside of a CompactPCI/PXI crate.
CAUTION: Do not exceed the maximum input voltage rating! The maximum input voltage for 50
Ω
input
impedance is
±
5 V. The maximum input for 1 M
Ω
input impedance is
±
100 V (dc + ac) except
for the DC2x1A/AR models where it is
±
300 V (dc + ac) .
1.6. Warning Regarding Medical Use
The Digitizer cards are not designed with components and testing procedures that would ensure a level of reliability
suitable for use in treatment and diagnosis of humans. Applications of these cards involving medical or clinical
treatment can create a potential for accidental injury caused by product failure, or by errors on the part of the user.
These cards are not intended to be a substitute for any form of established process or equipment used to monitor or
safeguard human health and safety in medical treatment.
WARNING: The modules discussed in this manual have not been designed for making direct measurements
on the human body. Users who connect an Acqiris module to a human body do so at their own
risk.