A SERVICE OF

logo

Chapter 2. Installation
61200226L1-1 ATLAS_800
PLUS
User Manual
2-5
Network Connection
The two eight-position modular jacks labeled
NTWK 1
and
NTWK 2
provide net-
work connection. Table 2-3 on page 2-6 shows the pinout for the network connec-
tors.
The two Network Interface (NI) ports comply with the applicable ANSI and
AT&T
®
standards.
The NIs provide the following functions:
AMI or B8ZS coding
Manual line build out
D4 or ESF framing
Network performance monitoring and reporting
Test loopbacks with QRSS generation and checking
Extensive self test
Connection
The network connection is as follows:
Table 2-2. Control Out/Chain Out Pinout
PIN NAME DESCRIPTION
1
GND Ground - connected to unit chassis.
Connect to GND of next unit (pin1).
2
UNUSED
3
TX DATA Data transmitted to chained units by the ATLAS.
Connect to RX DATA of the next unit (chain in pin 3).
4
UNUSED
5
RX DATA Data received from chained units by the ATLAS.
Connect to TX DATA of the next unit (chain in pin 5).
6,7,8
UNUSED
Connector type
(USOC) RJ-48C
Part number
AMP# 555164-2