the tare weight depending on the scale resolution (For example, in this
case, -1.45 would be used as the tare value).
If a PLU number is recalled that does not have any information stored
against it, the scale will continue to work with Tare and Unit weight
unchanged.
7.0 PARAMETERS
The parameters are split into 2 sections, one for the managers and the other
one for Technical.
7.1 USER PARAMETERS
Enter the User Parameters section by pressing the [Pst] key during the self-
test when the power is turned on. This will allow the user to set the way he
wants the scale to work by choosing specific values from some options.
Press the [U.Wt./Units] key to scroll through the other parameters. To
enter any parameter, press the [Print] key.
Press [U.Wt./Units] to scroll through the sub-parameters. To see the
earlier setting, press the [Print] key. To change and scroll through the
other available settings, press [U.Wt.]. To choose the desired setting
and thereby go back to the sub-parameter, press the [Print] key.
To return to the parameter, press the [Tare/Zero] key.
PARA-
METER
SUB-
PARAMETER
DISPLAYS AND SETTINGS
“bEEP"“ "oFF"”
Beeper is set to off
“bEEP"” "on I n "”
Beeper is set to on
between limits
F1 oFF bEEP
“bEEP” “"on oUt” ”
Beeper is set to on
outside limits (>0)
NOTE: PLU’s can be stored and recalled using RS-232 Interface (see
section 9.1 and 9.2 of this user Manual).