Note: When operating in this mode, the
Er. 2
error message displays at
startup or after material changes. To clear the error code and
silence the alarm, if installed, press the Clear key combination by
pressing and holding both the
CLEAR
UP key and DOWN key
together simultaneously.
enable a customer-supplied auxiliary proximity switch (
1
)
This proximity switch is typically mounted low in the machine bin
below the hopper loader, and is wired into the hopper loader as
shown in Figure (14). When enabled in this mode, the hopper loader
fills the machine bin below it, then stops operation.
Operation does not resume until the auxiliary proximity switch
senses that the material level has dropped below the proximity
switch. The hopper loader then refills the machine bin.
disable a customer-supplied proximity switch (
0
).
Set this parameter to
0
if you aren’t using an auxiliary proximity
switch or if you won’t be disabling an installed auxiliary proximity
switch.
Menu 8 SPI Communication Enable
Enable/Disable, Default = Disable (0 )
The SPI Communication Enable menu lets you:
enable the SPI communication function (
1
) if the hopper loader
has the SPI communication option installed and is on an SPI
network
disable the SPI communication function (
0
) if the SPI option is
installed, but the hopper loader is not currently on an SPI network
5-12 Shutting Down the Hopper Loader using the Series One Plus
Controller
Press the
S
START/STOP
START/STOP/SELECT/SET key to stop the hopper
loader.
For maintenance or for a long-term shutdown, unplug the unit from the power source and
shut off the compressed air supply.