OPERATING INSTRUCTIONS
06/01/2008
Detailed Operation
Heater Voltage is regulated by a Solid State Relay (SSR), which is turned ON and OFF
rapidly according to the temperature controller DC OUT signal. A “zero cross” type SSR
is used to minimize electrical noise.
Heater Element is protected with a resistive photo detector and a thermal resistor
(thermistor) mounted at the heater inlet. These sensors are connected in parallel with the
DC input signal going to the SSR.
o If the element overheats
(bright orange color) the photo detector resistance
decreases which reduces the control signal which, in turn, limits power to the
heater.
o If the air temperature in the housing reaches an unsafe level, the thermistor
resistance decreases which reduces the control signal, which in turn, limits power
to the heater.
o A small fixed resistor in series with the control signal sets element and air
temperature limits.
The large black dots on the wiring diagram represent connections that are made on the
internal terminal strip. The terminal strip allows the customer easy access to remove and
replace the heater element and blower if necessary.
4