VS-GSWG Swing Gate Operator Installation Guide
- 29 -
P1250 Revision X6 7-8-2011
Variable Speed Drive Programming
Programming the Hitachi Inverter
1. Apply power
2. Press FUNC
3. Use ▲▼ arrows to advance to F_ _ (F002 for L200)
4. Press FUNC arrow to get to F02 (L100 ONLY)
5. Press FUNC, arrows to change to 3.0 (3.00 for L200),
STR
6. Up arrow to advance to next parameter, (F03), FUNC
to view, arrows to change, STR to store and continue,
advance through listed parameters and store new values.
7. To switch from one letter prefi x to another, press FUNC
3 times, advance to desired letter prefi x, press FUNC,
advance to desired parameter.
8. When all parameters have been changed, advance to
D01, press FUNC, then press STR. This will display the
operating speed in Hz. (0-95)
CAUTION
This unit has been programmed at the factory. No changes
should be necessary for normal operation. PLEASE CONSULT
THE FACTORY BEFORE MAKING ANY CHANGES!
List of parameters set at factory
MODEL L100 MODEL L200
FUNCTION DESCRIPTION
RECOMMENDED
SETTING
FUNCTION DESCRIPTION
RECOMMENDED
SETTING
F02 ACCEL TIME 3.0 F002 ACCEL TIME 3.00
F03 DECEL TIME 3.0 F003 DECEL TIME 3.00
A01 SPEED SOURCE 00 (POT) A001 SPEED SOURCE 00 (POT)
A02 RUN COMMAND SOURCE 01 A002 RUN COMMAND SOURCE 01
A04 MAX SPEED 95.0 (Hz) A004 MAX SPEED 95 (Hz)
A20 TARGET SPEED 95.0 (Hz) A020 TARGET SPEED 95.0 (Hz)
A21 SECOND SPEED 20.0 (Hz) A021 SECOND SPEED 20.0 (Hz)
A042 AUTO TORQUE BOOST 0
A044 BOOST PERCENT 00
A081 AUTO VOLTAGE
REGULATION
01
A62 MIN SPEED 20.0 (Hz) A062 MIN SPEED 20.0 (Hz)
B01 AUTO RESET 01 B001 AUTO RESET 01
B130 INHIBIT DECEL
OVERVOLTAGE
01
C03 TERM 3 FUNC 03 C003 TERM 3 FUNC 03
C04 TERM 4 FUNC 11 C004 TERM 4 FUNC 11
C014 TERM 4 STATE 01
Figure 14. Hitachi L200 Inverter
NOTE: L200 model
must have this switch in
the UP (SR) position.
NOTE: L200 model must
have these two switches
in the DOWN position.