Hunter Fan 44273 Doll User Manual


 
44129-01 • 07/23/2012
30
4. The next Menu option is to set your thermostat’s primary span. Use
the or buttons to adjust between 1, 2, or, 3 degrees. Press
Next
after this has been changed or if no changes are necessary. The
span setting regulates when and how long your system will run. The
span has been set at the factory to 1 which will allow the system to
turn on 1
O
F (.05
O
C) above or below the set temperature and run for
1
O
F (.05
O
C) above or below the set temperature.
Example: If your thermostat is set to turn on at 72
O
in heat mode,
with a span setting of 2, your thermostat will activate your furnace at
71
O
and shut it down when it reaches 73
O
. For cooling at 72
O
with a
span of 2, your air conditioner will activate at 73
O
and shut down at
71
O
. This setting can be changed to 1, 2, or 3. 1 will shorten your
running time while 3 will lengthen it.
5. Unless you have a multi-stage conventional or heat pump system,
there is no need to change the second stage span. If you do, use the
or buttons to adjust between 1, 2, or, 3 degrees. Press
Next
once
this has been changed or if no changes are necessary. Secondary
span acts the same as your primary, but it determines when and how
long your second stage heat runs.
6. The last menu option changes your temperature readings between
Fahrenheit and Celcius. Use the or buttons to switch between
them and hit
Next
if you need to go back and make a change to a
different menu item, or
Done/
Home
to be returned to the home screen.
Menu Options