Graco 288400 Musical Toy Instrument User Manual


 
Before Beginning Repair
311327E 5
Before Beginning Repair
Flushing
Flush out fluid with new fluid, or flush out old fluid
with a compatible solvent before introducing new
fluid.
Use lowest possible pressure when flushing.
To flush entire system, circulate through gun fluid
manifold (with manifold removed from gun).
Always leave some type of fluid in system. Do not
use water.
Pressure Relief
Procedure
1. Select Park on Pump Control Switch.
2. Turn off feed pumps.
3. Trigger gun to relieve pressure.
4. Close gun inlet valves.
5. Close fluid supply inlet valves.
6. Service spray gun. See corresponding spray gun
manual.
Repairing this equipment requires access to parts
which may cause electric shock or other serious injury
if work is not performed properly. Electrical trouble-
shooting must be done by a qualified electrician. Be
sure to shut off all power to the equipment and lock out
power at the source before repairing.
Flush equipment only in a well-ventilated area. Do not
spray flammable fluids. Do not turn on heaters while
flushing with flammable solvents.
Trapped air can cause the pump to cycle unexpectedly,
which could result in serious injury from splashing or
moving parts.