Chief Manufacturing MSP-CM6HABV71/83 Crib Toy User Manual


 
MSP-CM6HABV71/83 Installation Instructions
12
these learned measurements, so that next time the system runs
it knows where to start and stop.
Status Light Codes
There is a light on the front of the mechanism motor box that
will tell through its pattern of flashes and colors what the
mechanism is doing.
Figure 13
Normal Doors At Rest - The Status Light will be on steady
green.
Normal Run Motion of Doors - The Status Light will flash in
groups of 2 green followed by a pause. In normal run motion
the doors on a Eubank mechanism have a variable speed. The
doors will start slowly, accelerate to a fast speed, and then slow
down before coming to a stop.
Doors Obstructed - The Status Light will flash in groups of 3
red followed by a pause. If the doors meet an obstruction they
will sense the obstruction, stop momentarily, and move in the
opposite direction for a few seconds. ---- Remove the
obstruction and then activate the doors. They should return to
normal run motion.
Doors Obstructed Both Ways - The Status Light will flash in
groups of 4 red followed by a pause. Similar to Doors
Obstructed but doors are prevented from moving in either
direction. ---- Remove the obstruction and then activate the
doors. They should return to normal run motion.
Travel Too Far - The Status Light will flash in groups of 5 red
followed by a pause. The motor is running but the doors are
not moving. ---- Has the motor box been uncoupled from the
track, or is the motor box bent, causing it to become uncoupled
from the track?
Power Loss - The Status Light will be on solid red. ---- There
has been a power loss (due to an electrical storm, etc.). When
next activated the doors will move at a slow speed to their full
closed position. If the doors are already closed they will not
move. The Status Light will return to solid green and the doors
are ready for normal activation.
Optional Control Input Connections
Control Input- 8 position RJ 45 modular phone jack
Discrete control for use with 3rd party control.
Position 8- Open
Position 7- Stop
IR Receiver “Eye” input for Eubank, Inc. supplied external IR
reciever only.
Position 6 - V out
Position 5 - Vcc, 5v
Radio Power for external RF reciever only.
Position 4 - 24 VDC
Sequence control for use with 3rd party control.
Position 3 - Sequence- Open, Stop, Close, Stop
Position 2 - Common
Discrete control for use with 3rd party control.
Position 1 - Close
Control Input on Front of Motor Box
Figure 14
NOTE: Making a momentary dry contact closure between the
common and the open, closed, stop, or sequence will
activate the system in that mode.
Status Indicator
Control Input
Figure 15
Control Input on Front of Motor Box