Installation Instructions MSP-CM6HABV71/83
11
RF Receiver Installation
Install RF reciever following the instructions provided with the
receiver.
System Activation
1. Insert plug from the power supply into the jack on the top of
the motor box.
Figure 9
2. Plug Powercord into 115VAC outlet.
IMPORTANT ! : A quality surge protection device is
recommended.
3. Make sure nothing is obstructing movement of doors,
4. Press and release the Activator Button on the front of the
Motor Box or the "Close Door button on the Remote Control.
(The doors should travel to the fully closed position)
Figure 10
5. Press the "Open Door" button on the Remote Control.
NOTE: The mechanism has been preset to travel 34 inches. If
a different travel distance is required see "Door Travel
Adjustment below.
ADJUSTMENTS
Adjust Door Travel Distance
To adjust door travel distance:
1. Set the length of travel required using the adjustable stop on
the bottom of the left hand track.
2. Press and hold the activator button on the front of the motor
box for 13 seconds.
The Status Light on the front of the motor box will begin to blink
alternately red and green. When this starts to happen release
the Activator Button. When put into "Learn Moden the system
runs back and forth several times and measures it's
environment, such as open and closed locations etc. The
system will then stop and remember these learned
measurements.
Figure 11
System Controls and Indicators
Learn Mode
The CM6SV system has no limit switches. The system uses an
encoder on the motor to collect data and send it to the micro
processor’s memory. The software "learns" about its
environment (speed, time duration, stop points, etc.) during the
initial setup of the unit and retains that information until
requested to "relearn" its environment.
The unit is shipped pre-set from the factory and will then
continually adjusts to it’s enviornment on each activation.
If for some reason you want to place the system into “Learn
Mode” (such as to stop at other than its normal stop points),
Press and hold the red activator button on the front of the motor
box for approxamatly 13 seconds and then release it when the
Status Light flashes quickly red, green, red, green, red, green.
Figure 12
The controller will then be in “Learn Mode” (The door will move
for 3 seconds, stop for 10 seconds, and when it starts moving
again it will be in it’s “Learn Mode”).
When put into “Learn Mode” the mechanism runs back and
forth several times and measures it’s environment, such as
open and closed locations etc., and then stops and remembers
24VDC Input
Top of
Cabinet
Front of
Cabinet
Activator
Activator
Activator Button