![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/f/43/f435f752-2ecd-4890-994f-ec6374c42606/f435f752-2ecd-4890-994f-ec6374c42606-bg4b.png)
Spinpoint M8-DVR Disti Product Manual REV 2.0
Each attribute data structure is assigned an attribute ID. Any non-zero value in the attribute ID number indicates
an active attribute. Valid values for this byte are found from 0x01 through 0xff. The attribute defined for
Spinpoint M8 are as follows:
Table 8-17 SMART Attribute Data List
ID
Errors during read operations.
Spin up time in millisecond
Number of Auto Reassign sectors
Errors during seek operations.
Off-line random seek time
ECC count for read operation
Read scan uncorrectable read error
Off-line scan pending sectors
Uncorrectable sector count
Off-line scan uncorrectable sectors.
CRC Errors during UDMA transfer
Errors during write operations.
Soft errors during read operations.
Off-line data collection status
The value of the off-line data collection status byte defines the current status of the off-line activities of the
device. Table6-15 lists the values and their respective definitions.
Table 8-18 Off-line Data Collection Status Values
Value Definition
00h or 80h Off-line data collection activity was never started.
01h Reserved
02h or 82h Off-line data collection activity was completed without error.
03h Reserved
04h or 84h Off-line data collection Activity was suspended by an interrupting command from host
05h or 85h Off-line data collection Activity was aborted by an interrupting command from host
06h or 86h Off-line data collection Activity was aborted by the device with a fatal error.
07h-3Fh Reserved
40h-7Fh Vendor specific
81h Reserved
83h Reserved
87h-BFh Reserved
C0h-FFh Vendor specific