![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/d/54/d54f2a8d-8ab3-454a-b068-9b7922ec7012/d54f2a8d-8ab3-454a-b068-9b7922ec7012-bge.png)
OPERATION
GROUNDINGTHEGENERATOR
TheNationalElectricalCoderequiresthattheframeand
externalelectricallyconductivepartsofthisgeneratorbe
properlyconnectedtoanapprovedearthground.Local
electricalcodesmayalsorequirepropergroundingof
theunit.Forthatpurpose,aGROUNDINGFASTENER
isprovidedonthegeneratorend(Figure).6
Generally,connectingaNo.12AWG(AmericanWire
Gauge)strandedcopperwiretothegroundingfastener
andtoanearth-drivencopperorbrassgroundingrod
(electrode)providesadequateprotectionagainstelec-
tricalshock.Becarefultokeepthegroundingwire
attachedafterconnectingthestrandedcopperwire.
However,localcodesmayvarywidely.
Properlygroundingthegeneratorhelpspreventelectrical
shockifagroundfaultconditionexistsinthegenerator
orinconnectedelectricaldevices,especiallywhenthe
unitisequippedwithawheelkit.Propergroundingalso
helpsdissipatestaticelectricity,whichoftenbuildsupin
ungroundeddevices.
Fig. 6
WARNING:
Consultwithalocalelectricianforgrounding
requirementsinyourarea.
Groundingfastener
14